Data quality metrics extracted from 5z14.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 5Z14 at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Experimental protocol
_diffrn_radiation.pdbx_diffrn_protocol
SINGLE WAVELENGTH
Source type
_diffrn_source.source
SYNCHROTRON
Source details
_diffrn_source.type
PHOTON FACTORY BEAMLINE BL-5A
Synchrotron site
_diffrn_source.pdbx_synchrotron_site
Photon Factory
Beamline
_diffrn_source.pdbx_synchrotron_beamline
BL-5A
Temperature [K]
_diffrn.ambient_temp
95
Detector technology
_diffrn_detector.detector
CCD
Collection date
_diffrn_detector.pdbx_collection_date
2016-11-18
Detector
_diffrn_detector.type
ADSC QUANTUM 315r
Wavelength(s) [Å]
_diffrn_source.pdbx_wavelength_list
1.0000
Software
Data reduction
_software.classification
iMOSFLM
Data scaling
_software.classification
SCALA
Phasing
_software.classification
MOLREP
Refinement
_software.classification
REFMAC (5.8.0073)
General information
Spacegroup name
_symmetry.space_group_name_H-M
C 1 2 1
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
143.51 99.00 139.49 90.00 108.51 90.00
Wavelength
_diffrn_radiation_wavelength.wavelength
1.00000 Å

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
132.270
High resolution limit [Å]
_reflns.d_resolution_high
2.800
  Rmerge -
  Rmeas -
  Rpim -
  Total number of observations -
Total number unique
_reflns.number_obs
43515
<I/σ(I)>
_reflns.pdbx_netI_over_sigmaI
14.20
Completeness [%]
_reflns.percent_possible_obs
99.0
Multiplicity
_reflns.pdbx_redundancy
6.4
  CC(1/2) -

Refinement
PDB entry ID
_entry.id
5Z14
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
2017-12-25
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
44.1 - 2.800 Å
Rwork/Rfree
_refine.ls_R_factor_R_work _refine.ls_R_factor_R_free
0.2006 / 0.2770