Data quality metrics extracted from 4xxu.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 4XXU at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Experimental protocol
_diffrn_radiation.pdbx_diffrn_protocol
SINGLE WAVELENGTH
Source type
_diffrn_source.source
SYNCHROTRON
Source details
_diffrn_source.type
APS BEAMLINE 22-ID
Synchrotron site
_diffrn_source.pdbx_synchrotron_site
APS
Beamline
_diffrn_source.pdbx_synchrotron_beamline
22-ID
Temperature [K]
_diffrn.ambient_temp
100
Detector technology
_diffrn_detector.detector
CCD
Collection date
_diffrn_detector.pdbx_collection_date
2013-10-15
Detector
_diffrn_detector.type
RAYONIX MX-300
Wavelength(s) [Å]
_diffrn_source.pdbx_wavelength_list
0.97872
Software
Refinement
_software.classification
PHENIX (PHENIX.REFINE: 1.8.2_1309)
General information
Spacegroup name
_symmetry.space_group_name_H-M
P 31
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
84.049 84.049 60.239 90.0 90.0 120.0
Wavelength
_diffrn_radiation_wavelength.wavelength
0.97872 Å

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
50.000
High resolution limit [Å]
_reflns.d_resolution_high
1.430
  Rmerge -
  Rmeas -
  Rpim -
  Total number of observations -
Total number unique
_reflns.number_obs
86664
<I/σ(I)>
_reflns.pdbx_netI_over_sigmaI
3.48
Completeness [%]
_reflns.percent_possible_obs
99.5
Multiplicity
_reflns.pdbx_redundancy
5.6
  CC(1/2) -

Refinement
PDB entry ID
_entry.id
4XXU
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
2015-01-30
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
34.5 - 1.430 Å
Rwork/Rfree
_refine.ls_R_factor_R_work _refine.ls_R_factor_R_free
0.1600 / 0.1800