| Experiment | |
|---|---|
Method _exptl.method | NEUTRON DIFFRACTION |
Experimental protocol _diffrn_radiation.pdbx_diffrn_protocol | LAUE |
Source type _diffrn_source.source | SPALLATION SOURCE |
Source details _diffrn_source.type | J-PARC MLF BEAMLINE BL-03 |
Synchrotron site _diffrn_source.pdbx_synchrotron_site | JPARC MLF |
Beamline _diffrn_source.pdbx_synchrotron_beamline | BL-03 |
Temperature [K] _diffrn.ambient_temp | 100 |
Detector technology _diffrn_detector.detector | DIFFRACTOMETER |
Collection date _diffrn_detector.pdbx_collection_date | 2015-11-10 |
Detector _diffrn_detector.type | iBIX |
Wavelength(s) [Å] _diffrn_source.pdbx_wavelength_list | 3.0-5.7 |
| Software | |
Data reduction _software.classification | HKL-2000 |
Data scaling _software.classification | XDS |
Phasing _software.classification | PHASER |
Refinement _software.classification | PHENIX (1.19.2_4158: ???) |
| General information | |
Spacegroup name _symmetry.space_group_name_H-M | C 1 2 1 |
Unit cell parameters _cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma} | 157.548 61.779 92.232 90.00 112.13 90.00 |
Wavelength _diffrn_radiation_wavelength.wavelength | 3.000005.70000 Å |
| Data quality metrics | Overall | OuterShell |
|---|---|---|
Low resolution limit [Å] _reflns.d_resolution_low _reflns_shell.d_res_low | 20.940 | 1.780 |
High resolution limit [Å] _reflns.d_resolution_high _reflns_shell.d_res_high | 1.720 | 1.720 |
| Rmerge | - | - |
| Rmeas | - | - |
| Rpim | - | - |
| Total number of observations | - | - |
Total number unique _reflns.number_obs | 76306 | - |
<I/σ(I)> _reflns.pdbx_netI_over_sigmaI | 4.99 | - |
Completeness [%] _reflns.percent_possible_obs | 87.4 | - |
Multiplicity _reflns.pdbx_redundancy | 2.7 | - |
| CC(1/2) | - | - |
| Refinement | |
|---|---|
PDB entry ID _entry.id | 7WNO |
Deposition date _pdbx_database_status.recvd_initial_deposition_date | 2022-01-19 |
Resolution _refine.ls_d_res_low _refine.ls_d_res_high | 20.9 - 1.720 Å |
Rwork/Rfree _refine.ls_R_factor_R_work _refine.ls_R_factor_R_free | 0.1630 / 0.2570 |
Structure solution method _refine.pdbx_method_to_determine_struct | MIR |