Data quality metrics extracted from 4v4k.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 4V4K at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Experimental protocol
_diffrn_radiation.pdbx_diffrn_protocol
SINGLE WAVELENGTH
Source type
_diffrn_source.source
SYNCHROTRON
Source details
_diffrn_source.type
CHESS BEAMLINE A1
Synchrotron site
_diffrn_source.pdbx_synchrotron_site
CHESS
Beamline
_diffrn_source.pdbx_synchrotron_beamline
A1
Temperature [K]
_diffrn.ambient_temp
100
Detector technology
_diffrn_detector.detector
CCD
Collection date
_diffrn_detector.pdbx_collection_date
2006-05-01
Detector
_diffrn_detector.type
ADSC QUANTUM 210
Software
Data reduction
_software.classification
HKL-2000
Data scaling
_software.classification
HKL-2000
Phasing #1
_software.classification
PHASER
Phasing #2
_software.classification
DM
Model building
_software.classification
DM
Refinement
_software.classification
PHENIX (PHENIX.REFINE: 1.5_2)
General information
Spacegroup name
_symmetry.space_group_name_H-M
P 1 21 1
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
170.172 253.284 282.730 90.00 90.68 90.00
Wavelength
_diffrn_radiation_wavelength.wavelength
0.98700 Å

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
100.000
High resolution limit [Å]
_reflns.d_resolution_high
3.250
Rmerge
_reflns.pdbx_Rsym_value
0.149
  Rmeas -
  Rpim -
  Total number of observations -
Total number unique
_reflns.number_obs
484105
<I/σ(I)>
_reflns.pdbx_netI_over_sigmaI
8.70
Completeness [%]
_reflns.percent_possible_obs
92.2
Multiplicity
_reflns.pdbx_redundancy
2.9
  CC(1/2) -

Refinement
PDB entry ID
_entry.id
4V4K
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
2010-04-19
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
20.0 - 3.251 Å
Rwork/Rfree
_refine.ls_R_factor_R_work _refine.ls_R_factor_R_free
0.2223 / 0.2365