Data quality metrics extracted from 4u5v.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 4U5V at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Experimental protocol
_diffrn_radiation.pdbx_diffrn_protocol
SINGLE WAVELENGTH
Source type
_diffrn_source.source
SYNCHROTRON
Source details
_diffrn_source.type
ESRF BEAMLINE ID14-4
Synchrotron site
_diffrn_source.pdbx_synchrotron_site
ESRF
Beamline
_diffrn_source.pdbx_synchrotron_beamline
ID14-4
Temperature [K]
_diffrn.ambient_temp
100
Detector technology
_diffrn_detector.detector
CCD
Collection date
_diffrn_detector.pdbx_collection_date
2013-09-28
Detector
_diffrn_detector.type
ADSC QUANTUM 315r
Wavelength(s) [Å]
_diffrn_source.pdbx_wavelength_list
0.9763
Software
Refinement
_software.classification
PHENIX (phenix.refine: dev_1702)
General information
Spacegroup name
_symmetry.space_group_name_H-M
P 21 21 21
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
79.041 90.828 99.745 90.0 90.0 90.0
Wavelength
_diffrn_radiation_wavelength.wavelength
0.97630 Å

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
67.100
High resolution limit [Å]
_reflns.d_resolution_high
1.950
  Rmerge -
  Rmeas -
  Rpim -
  Total number of observations -
Total number unique
_reflns.number_obs
49375
<I/σ(I)>
_reflns.pdbx_netI_over_sigmaI
13.60
Completeness [%]
_reflns.percent_possible_obs
96.8
Multiplicity
_reflns.pdbx_redundancy
4.3
  CC(1/2) -

Refinement
PDB entry ID
_entry.id
4U5V
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
2014-07-25
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
41.3 - 1.968 Å
Rwork/Rfree
_refine.ls_R_factor_R_work _refine.ls_R_factor_R_free
0.2297 / 0.2593