Data quality metrics extracted from 1ruh.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 1RUH at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Source type
_diffrn_source.source
SYNCHROTRON
Source details
_diffrn_source.type
CHESS BEAMLINE A1
Synchrotron site
_diffrn_source.pdbx_synchrotron_site
CHESS
Beamline
_diffrn_source.pdbx_synchrotron_beamline
A1
Detector technology
_diffrn_detector.detector
FILM
Collection date
_diffrn_detector.pdbx_collection_date
1990-08
Detector
_diffrn_detector.type
KODAK
Software
Data reduction
_software.classification
PURDUE (DATA PROCESSING PACKAGE)
Model building
_software.classification
O
General information
Spacegroup name
_symmetry.space_group_name_H-M
P 21 3
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
445.1 445.1 445.1 90.0 90.0 90.0
Wavelength
_diffrn_radiation_wavelength.wavelength
0.97800 Å

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
30.000
High resolution limit [Å]
_reflns.d_resolution_high
3.000
Rmerge
_reflns.pdbx_Rmerge_I_obs
0.121
  Rmeas -
  Rpim -
  Total number of observations -
Total number unique
_reflns.number_obs
48084
  <I/σ(I)> -
Completeness [%]
_reflns.percent_possible_obs
10.0
  Multiplicity -
  CC(1/2) -

Refinement
PDB entry ID
_entry.id
1RUH
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
1995-06-09