Data quality metrics extracted from 7oqd.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 7OQD at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Experimental protocol
_diffrn_radiation.pdbx_diffrn_protocol
SINGLE WAVELENGTH
Source type
_diffrn_source.source
LIQUID ANODE
Source details
_diffrn_source.type
BRUKER METALJET
Temperature [K]
_diffrn.ambient_temp
100
Detector technology
_diffrn_detector.detector
PIXEL
Collection date
_diffrn_detector.pdbx_collection_date
2021-05-29
Detector
_diffrn_detector.type
Bruker PHOTON III
Wavelength(s) [Å]
_diffrn_source.pdbx_wavelength_list
1.34
Software
Data reduction
_software.classification
SAINT
Data scaling
_software.classification
SAINT
Phasing
_software.classification
PHASER
Refinement
_software.classification
REFMAC (5.8.0267)
General information
Spacegroup name
_symmetry.space_group_name_H-M
P 21 21 21
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
76.175 79.196 91.100 90.0 90.0 90.0
Wavelength
_diffrn_radiation_wavelength.wavelength
1.34000 Å

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
18.523
High resolution limit [Å]
_reflns.d_resolution_high
2.300
  Rmerge -
  Rmeas -
  Rpim -
  Total number of observations -
Total number unique
_reflns.number_obs
24826
<I/σ(I)>
_reflns.pdbx_netI_over_sigmaI
4.80
Completeness [%]
_reflns.percent_possible_obs
98.8
Multiplicity
_reflns.pdbx_redundancy
4.0
CC(1/2)
_reflns.pdbx_CC_half
0.968

Refinement
PDB entry ID
_entry.id
7OQD
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
2021-06-03
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
18.5 - 2.300 Å
Rwork/Rfree
_refine.ls_R_factor_R_work _refine.ls_R_factor_R_free
0.2381 / 0.2884
Structure solution method
_refine.pdbx_method_to_determine_struct
MOLECULAR REPLACEMENT
Starting model (for MR)
_refine.pdbx_starting_model
7AN1