Data quality metrics extracted from 5nqc.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 5NQC at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Experimental protocol
_diffrn_radiation.pdbx_diffrn_protocol
SINGLE WAVELENGTH
Source type
_diffrn_source.source
ROTATING ANODE
Source details
_diffrn_source.type
BRUKER AXS MICROSTAR
Temperature [K]
_diffrn.ambient_temp
100
Detector technology
_diffrn_detector.detector
CCD
Collection date
_diffrn_detector.pdbx_collection_date
2012-08-28
Detector
_diffrn_detector.type
Bruker Platinum 135
Wavelength(s) [Å]
_diffrn_source.pdbx_wavelength_list
1.5406
Software
Data reduction
_software.classification
PROTEUM PLUS
Data scaling
_software.classification
PROTEUM PLUS
Phasing
_software.classification
PHENIX
Refinement
_software.classification
PHENIX (1.7.3_928)
General information
Spacegroup name
_symmetry.space_group_name_H-M
P 43 21 2
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
71.477 71.477 126.266 90.0 90.0 90.0
Wavelength
_diffrn_radiation_wavelength.wavelength
1.54060 Å

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
28.880
High resolution limit [Å]
_reflns.d_resolution_high
2.000
  Rmerge -
  Rmeas -
  Rpim -
  Total number of observations -
Total number unique
_reflns.number_obs
22847
<I/σ(I)>
_reflns.pdbx_netI_over_sigmaI
11.91
Completeness [%]
_reflns.percent_possible_obs
99.7
Multiplicity
_reflns.pdbx_redundancy
7.6
  CC(1/2) -

Refinement
PDB entry ID
_entry.id
5NQC
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
2017-04-19
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
28.9 - 2.000 Å
Rwork/Rfree
_refine.ls_R_factor_R_work _refine.ls_R_factor_R_free
0.1962 / 0.2472
Structure solution method
_refine.pdbx_method_to_determine_struct
MOLECULAR REPLACEMENT
Starting model (for MR)
_refine.pdbx_starting_model
3Q04