Data quality metrics extracted from 1n3r.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 1N3R at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Experimental protocol
_diffrn_radiation.pdbx_diffrn_protocol
SINGLE WAVELENGTH
Source type
_diffrn_source.source
SYNCHROTRON
Source details
_diffrn_source.type
MPG/DESY, HAMBURG BEAMLINE BW6
Synchrotron site
_diffrn_source.pdbx_synchrotron_site
MPG/DESY, HAMBURG
Beamline
_diffrn_source.pdbx_synchrotron_beamline
BW6
Temperature [K]
_diffrn.ambient_temp
100.0
Detector technology
_diffrn_detector.detector
CCD
Collection date
_diffrn_detector.pdbx_collection_date
2001-12-10
Detector
_diffrn_detector.type
MARRESEARCH
Software
Data reduction
_software.classification
MOSFLM
Data scaling #1
_software.classification
SCALA
Data scaling #2
_software.classification
CCP4 (SCALA)
Phasing
_software.classification
MOLREP
Refinement
_software.classification
CNS
General information
Spacegroup name
_symmetry.space_group_name_H-M
C 2 2 21
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
224.466 313.258 130.181 90.0 90.0 90.0
Wavelength
_diffrn_radiation_wavelength.wavelength
NA

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
20.000
High resolution limit [Å]
_reflns.d_resolution_high
2.800
  Rmerge -
  Rmeas -
  Rpim -
  Total number of observations -
Total number unique
_reflns.number_obs
105682
  <I/σ(I)> -
Completeness [%]
_reflns.percent_possible_obs
97.4
  Multiplicity -
  CC(1/2) -

Refinement
PDB entry ID
_entry.id
1N3R
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
2002-10-29
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
20.0 - 2.800 Å
Rwork/Rfree
_refine.ls_R_factor_R_work _refine.ls_R_factor_R_free
0.2180 / 0.2720
Structure solution method
_refine.pdbx_method_to_determine_struct
MOLECULAR REPLACEMENT
Starting model (for MR)
_refine.pdbx_starting_model
WARNING: no starting model (for MR) given