Data quality metrics extracted from 5mqc.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 5MQC at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Experimental protocol
_diffrn_radiation.pdbx_diffrn_protocol
SINGLE WAVELENGTH
Source type
_diffrn_source.source
SYNCHROTRON
Source details
_diffrn_source.type
SOLEIL BEAMLINE PROXIMA 1
Synchrotron site
_diffrn_source.pdbx_synchrotron_site
SOLEIL
Beamline
_diffrn_source.pdbx_synchrotron_beamline
PROXIMA 1
Temperature [K]
_diffrn.ambient_temp
80
Detector technology
_diffrn_detector.detector
PIXEL
Collection date
_diffrn_detector.pdbx_collection_date
2015-12-02
Detector
_diffrn_detector.type
DECTRIS PILATUS 6M
Wavelength(s) [Å]
_diffrn_source.pdbx_wavelength_list
1.0
Software
Refinement #1
_software.classification
PHENIX
Refinement #2
_software.classification
CNS
General information
Spacegroup name
_symmetry.space_group_name_H-M
I 2 2 2
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
332.914 350.962 362.540 90.0 90.0 90.0
Wavelength
_diffrn_radiation_wavelength.wavelength
1.00000 Å

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
39.810
High resolution limit [Å]
_reflns.d_resolution_high
3.400
Rmerge
_reflns.pdbx_Rmerge_I_obs
0.208
  Rmeas -
  Rpim -
  Total number of observations -
Total number unique
_reflns.number_obs
193433
<I/σ(I)>
_reflns.pdbx_netI_over_sigmaI
3.70
Completeness [%]
_reflns.percent_possible_obs
68.1
Multiplicity
_reflns.pdbx_redundancy
1.9
  CC(1/2) -

Refinement
PDB entry ID
_entry.id
5MQC
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
2016-12-20
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
39.8 - 3.400 Å
Rwork
_refine.ls_R_factor_R_work
0.2466
WARNING: no Rfree given (but Rwork)!?
Structure solution method
_refine.pdbx_method_to_determine_struct
MOLECULAR REPLACEMENT
Starting model (for MR)
_refine.pdbx_starting_model
1b35