Data quality metrics extracted from 1ldy.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 1LDY at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Source type
_diffrn_source.source
SYNCHROTRON
Source details
_diffrn_source.type
EMBL/DESY, HAMBURG BEAMLINE X31
Synchrotron site
_diffrn_source.pdbx_synchrotron_site
EMBL/DESY, HAMBURG
Beamline
_diffrn_source.pdbx_synchrotron_beamline
X31
Temperature [K]
_diffrn.ambient_temp
100
Detector technology
_diffrn_detector.detector
IMAGE PLATE
Collection date
_diffrn_detector.pdbx_collection_date
1996-06
Detector
_diffrn_detector.type
MARRESEARCH
Software
Data reduction
_software.classification
DENZO
Data scaling
_software.classification
SCALEPACK
Refinement
_software.classification
REFMAC
General information
Spacegroup name
_symmetry.space_group_name_H-M
P 1 21 1
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
49.93 180.20 86.80 90.0 106.0 90.0
Wavelength
_diffrn_radiation_wavelength.wavelength
0.99000 Å

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
12.000
High resolution limit [Å]
_reflns.d_resolution_high
2.500
Rmerge
_reflns.pdbx_Rsym_value
0.042
  Rmeas -
  Rpim -
  Total number of observations -
  Total number unique -
<I/σ(I)>
_reflns.pdbx_netI_over_sigmaI
21.86
Completeness [%]
_reflns.percent_possible_obs
92.9
Multiplicity
_reflns.pdbx_redundancy
2.6
  CC(1/2) -

Refinement
PDB entry ID
_entry.id
1LDY
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
1996-12-23
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
12.0 - 2.500 Å
Rwork
_refine.ls_R_factor_R_work
0.2070
WARNING: no Rfree given (but Rwork)!?