Data quality metrics extracted from 1hfp.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 1HFP at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Detector technology
_diffrn_detector.detector
IMAGE PLATE
Collection date
_diffrn_detector.pdbx_collection_date
1993-05-05
Detector
_diffrn_detector.type
RIGAKU
Software
Data reduction
_software.classification
R-AXIS (II)
Refinement
_software.classification
PROFFT
General information
Spacegroup name
_symmetry.space_group_name_H-M
H 3
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
87.120 87.120 77.014 90.0 90.0 120.0
Wavelength
_diffrn_radiation_wavelength.wavelength
1.54180 Å

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
8.000
High resolution limit [Å]
_reflns.d_resolution_high
1.900
Rmerge
_reflns.pdbx_Rmerge_I_obs
0.056
  Rmeas -
  Rpim -
  Total number of observations -
Total number unique
_reflns.number_obs
11985
  <I/σ(I)> -
Completeness [%]
_reflns.percent_possible_obs
70.0
Multiplicity
_reflns.pdbx_redundancy
3.1
  CC(1/2) -

Refinement
PDB entry ID
_entry.id
1HFP
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
1997-11-04
Rwork
_refine.ls_R_factor_R_work
0.1814
WARNING: no Rfree given (but Rwork)!?