Data quality metrics extracted from 2ey4.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 2EY4 at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Experimental protocol
_diffrn_radiation.pdbx_diffrn_protocol
MAD
Source type
_diffrn_source.source
SYNCHROTRON
Source details
_diffrn_source.type
APS BEAMLINE 8-BM
Synchrotron site
_diffrn_source.pdbx_synchrotron_site
APS
Beamline
_diffrn_source.pdbx_synchrotron_beamline
8-BM
Temperature [K]
_diffrn.ambient_temp
173
Detector technology
_diffrn_detector.detector
CCD
Collection date
_diffrn_detector.pdbx_collection_date
2005-03-26
Detector
_diffrn_detector.type
MARRESEARCH
Wavelength(s) [Å]
_diffrn_source.pdbx_wavelength_list
0.9792, 0.9794, 0.9537
Software
Data reduction
_software.classification
bioteX
Phasing
_software.classification
CNS
Refinement
_software.classification
CNS (1.1)
General information
Spacegroup name
_symmetry.space_group_name_H-M
P 1
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
36.087 75.361 103.240 95.90 96.90 94.99
Wavelength
_diffrn_radiation_wavelength.wavelength
1.000000.979200.979400.95370 Å

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
50.000
High resolution limit [Å]
_reflns.d_resolution_high
2.100
  Rmerge -
  Rmeas -
  Rpim -
  Total number of observations -
Total number unique
_reflns.number_obs
51837
  <I/σ(I)> -
Completeness [%]
_reflns.percent_possible_obs
55.6
  Multiplicity -
  CC(1/2) -

Refinement
PDB entry ID
_entry.id
2EY4
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
2005-11-09
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
40.0 - 2.110 Å
Rwork/Rfree
_refine.ls_R_factor_R_work _refine.ls_R_factor_R_free
0.2110 / 0.2550
Structure solution method
_refine.pdbx_method_to_determine_struct
MAD