Data quality metrics extracted from 1eut.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 1EUT at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Source type
_diffrn_source.source
SYNCHROTRON
Source details
_diffrn_source.type
EMBL/DESY, HAMBURG BEAMLINE X11
Synchrotron site
_diffrn_source.pdbx_synchrotron_site
EMBL/DESY, HAMBURG
Beamline
_diffrn_source.pdbx_synchrotron_beamline
X11
Detector technology
_diffrn_detector.detector
IMAGE PLATE
Collection date
_diffrn_detector.pdbx_collection_date
1995-05
Detector
_diffrn_detector.type
MARRESEARCH
Software
Data reduction
_software.classification
DENZO
Phasing
_software.classification
X-PLOR (3.1)
Model building
_software.classification
X-PLOR (3.1)
Refinement
_software.classification
X-PLOR (3.1)
General information
Spacegroup name
_symmetry.space_group_name_H-M
P 1 21 1
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
51.28 117.30 60.24 90.00 96.17 90.00
Wavelength
_diffrn_radiation_wavelength.wavelength
0.99300 Å

Refinement
PDB entry ID
_entry.id
1EUT
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
1996-06-21
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
6.0 - 2.500 Å
R
_refine.ls_R_factor_obs
0.2140
Rwork
_refine.ls_R_factor_R_work
0.2140
WARNING: no Rfree given?