Data quality metrics extracted from 1del.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 1DEL at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Source type
_diffrn_source.source
SYNCHROTRON
Source details
_diffrn_source.type
EMBL/DESY, HAMBURG BEAMLINE X11
Synchrotron site
_diffrn_source.pdbx_synchrotron_site
EMBL/DESY, HAMBURG
Beamline
_diffrn_source.pdbx_synchrotron_beamline
X11
Temperature [K]
_diffrn.ambient_temp
277
Detector technology
_diffrn_detector.detector
IMAGE PLATE
Collection date
_diffrn_detector.pdbx_collection_date
1995-04-01
Detector
_diffrn_detector.type
MAR scanner 180 mm plate
Software
Data reduction
_software.classification
DENZO
Refinement
_software.classification
PROLSQ
General information
Spacegroup name
_symmetry.space_group_name_H-M
C 1 2 1
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
155.2 58.5 75.7 90.0 108.1 90.0
Wavelength
_diffrn_radiation_wavelength.wavelength
0.92000 Å

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
10.000
High resolution limit [Å]
_reflns.d_resolution_high
2.200
Rmerge
_reflns.pdbx_Rmerge_I_obs
0.065
  Rmeas -
  Rpim -
  Total number of observations -
Total number unique
_reflns.number_obs
31836
  <I/σ(I)> -
Completeness [%]
_reflns.percent_possible_obs
96.5
Multiplicity
_reflns.pdbx_redundancy
3.0
  CC(1/2) -

Refinement
PDB entry ID
_entry.id
1DEL
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
1996-01-09
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
10.0 - 2.200 Å
Rwork
_refine.ls_R_factor_R_work
0.1860
WARNING: no Rfree given (but Rwork)!?