Data quality metrics extracted from 1d8y.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 1D8Y at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Experimental protocol
_diffrn_radiation.pdbx_diffrn_protocol
SINGLE WAVELENGTH
Source type
_diffrn_source.source
SYNCHROTRON
Source details
_diffrn_source.type
APS BEAMLINE 5ID-B
Synchrotron site
_diffrn_source.pdbx_synchrotron_site
APS
Beamline
_diffrn_source.pdbx_synchrotron_beamline
5ID-B
Temperature [K]
_diffrn.ambient_temp
120
Detector technology
_diffrn_detector.detector
CCD
Collection date
_diffrn_detector.pdbx_collection_date
1998-05-31
Detector
_diffrn_detector.type
MARRESEARCH
Software
Data reduction
_software.classification
DENZO
Data scaling
_software.classification
SCALEPACK
Phasing
_software.classification
AMoRE
Refinement
_software.classification
CNS
General information
Spacegroup name
_symmetry.space_group_name_H-M
P 43
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
101.88 101.88 85.18 90.0 90.0 90.0
Wavelength
_diffrn_radiation_wavelength.wavelength
0.99503 Å

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
35.000
High resolution limit [Å]
_reflns.d_resolution_high
2.080
Rmerge
_reflns.pdbx_Rmerge_I_obs
0.050
  Rmeas -
  Rpim -
  Total number of observations -
Total number unique
_reflns.number_obs
49466
  <I/σ(I)> -
Completeness [%]
_reflns.percent_possible_obs
94.6
Multiplicity
_reflns.pdbx_redundancy
2.6
  CC(1/2) -

Refinement
PDB entry ID
_entry.id
1D8Y
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
1999-10-26
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
20.0 - 2.080 Å
Rwork/Rfree
_refine.ls_R_factor_R_work _refine.ls_R_factor_R_free
0.2170 / 0.2330