Data quality metrics extracted from 1cwn.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 1CWN at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Source type
_diffrn_source.source
SYNCHROTRON
Source details
_diffrn_source.type
NSLS BEAMLINE X8C
Synchrotron site
_diffrn_source.pdbx_synchrotron_site
NSLS
Beamline
_diffrn_source.pdbx_synchrotron_beamline
X8C
Temperature [K]
_diffrn.ambient_temp
108
Detector technology
_diffrn_detector.detector
CCD
Collection date
_diffrn_detector.pdbx_collection_date
1995-06-15
Software
Data reduction
_software.classification
MADNES
Refinement
_software.classification
X-PLOR
General information
Spacegroup name
_symmetry.space_group_name_H-M
P 65 2 2
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
67.2 67.2 243.7 90.0 90.0 120.0
Wavelength
_diffrn_radiation_wavelength.wavelength
1.00615 Å

Refinement
PDB entry ID
_entry.id
1CWN
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
1996-07-30
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
6.0 - 2.000 Å
R
_refine.ls_R_factor_obs
0.2000
Rwork
_refine.ls_R_factor_R_work
0.2000
WARNING: no Rfree given?