Data quality metrics extracted from 1cno.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 1CNO at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Source type
_diffrn_source.source
SYNCHROTRON
Source details
_diffrn_source.type
ESRF BEAMLINE ID09
Synchrotron site
_diffrn_source.pdbx_synchrotron_site
ESRF
Beamline
_diffrn_source.pdbx_synchrotron_beamline
ID09
Temperature [K]
_diffrn.ambient_temp
100
Detector technology
_diffrn_detector.detector
X RAY IMAGE INTENSIFIER (THOMPSON) + PRINCETON CCD DETECTOR
Collection date
_diffrn_detector.pdbx_collection_date
1998-05
Detector
_diffrn_detector.type
THOMPSON
Software
Data reduction #1
_software.classification
DENZO
Data reduction #2
_software.classification
PROW
Data scaling
_software.classification
CCP4 (SCALA)
Phasing
_software.classification
X-PLOR (3.843)
Model building
_software.classification
X-PLOR (3.843)
Refinement
_software.classification
X-PLOR (3.843)
General information
Spacegroup name
_symmetry.space_group_name_H-M
P 31 1 2
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
121.8 121.8 136.1 90.0 90.0 120.0
Wavelength
_diffrn_radiation_wavelength.wavelength
0.75600 Å

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
15.000
High resolution limit [Å]
_reflns.d_resolution_high
2.200
Rmerge
_reflns.pdbx_Rsym_value
0.108
  Rmeas -
  Rpim -
  Total number of observations -
Total number unique
_reflns.number_obs
58183
<I/σ(I)>
_reflns.pdbx_netI_over_sigmaI
6.30
Completeness [%]
_reflns.percent_possible_obs
99.0
Multiplicity
_reflns.pdbx_redundancy
3.5
  CC(1/2) -

Refinement
PDB entry ID
_entry.id
1CNO
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
1998-08-03
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
15.0 - 2.200 Å
Rwork/Rfree
_refine.ls_R_factor_R_work _refine.ls_R_factor_R_free
0.1784 / 0.2080