Data quality metrics extracted from 1cec.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 1CEC at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Source type
_diffrn_source.source
SYNCHROTRON
Source details
_diffrn_source.type
EMBL/DESY, HAMBURG BEAMLINE X11
Synchrotron site
_diffrn_source.pdbx_synchrotron_site
EMBL/DESY, HAMBURG
Beamline
_diffrn_source.pdbx_synchrotron_beamline
X11
Detector technology
_diffrn_detector.detector
IMAGE PLATE
Collection date
_diffrn_detector.pdbx_collection_date
1993-11
Detector
_diffrn_detector.type
MARRESEARCH
Software
Data reduction
_software.classification
DENZO
Phasing
_software.classification
X-PLOR
Model building #1
_software.classification
ARP/wARP
Model building #2
_software.classification
X-PLOR
Refinement
_software.classification
X-PLOR
General information
Spacegroup name
_symmetry.space_group_name_H-M
P 21 21 21
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
51.40 84.33 87.50 90.0 90.0 90.0
Wavelength
_diffrn_radiation_wavelength.wavelength
0.92000 Å

Refinement
PDB entry ID
_entry.id
1CEC
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
1995-06-07
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
6.0 - 2.150 Å
Rwork/Rfree
_refine.ls_R_factor_R_work _refine.ls_R_factor_R_free
0.1680 / 0.2150