Data quality metrics extracted from 1c8d.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 1C8D at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Experimental protocol
_diffrn_radiation.pdbx_diffrn_protocol
SINGLE WAVELENGTH
Source type
_diffrn_source.source
SYNCHROTRON
Source details
_diffrn_source.type
CHESS BEAMLINE F1
Synchrotron site
_diffrn_source.pdbx_synchrotron_site
CHESS
Beamline
_diffrn_source.pdbx_synchrotron_beamline
F1
Temperature [K]
_diffrn.ambient_temp
277
Detector technology
_diffrn_detector.detector
IMAGE PLATE
Collection date
_diffrn_detector.pdbx_collection_date
1995-01-15
Detector
_diffrn_detector.type
FUJI
Software
Phasing #1
_software.classification
GLRF
Phasing #2
_software.classification
ENVELOPE
Model building
_software.classification
ENVELOPE
Refinement
_software.classification
CNS (0.5)
General information
Spacegroup name
_symmetry.space_group_name_H-M
P 1
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
267.563 268.446 274.328 61.946 62.616 60.186
Wavelength
_diffrn_radiation_wavelength.wavelength
0.91800 Å

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
50.000
High resolution limit [Å]
_reflns.d_resolution_high
3.000
Rmerge
_reflns.pdbx_Rmerge_I_obs
0.090
  Rmeas -
  Rpim -
  Total number of observations -
Total number unique
_reflns.number_obs
322866
  <I/σ(I)> -
Completeness [%]
_reflns.percent_possible_obs
31.3
  Multiplicity -
  CC(1/2) -

Refinement
PDB entry ID
_entry.id
1C8D
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
2000-05-05
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
9.0 - 3.000 Å
R
_refine.ls_R_factor_obs
0.2140
WARNING: neither Rwork nor Rfree given