Data quality metrics extracted from 7c4u.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 7C4U at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
ELECTRON CRYSTALLOGRAPHY
Collection date
_diffrn_detector.pdbx_collection_date
2019-06-01
Software
Refinement
_software.classification
PHENIX (1.15_3459)
General information
Spacegroup name
_symmetry.space_group_name_H-M
P 2 21 21
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
20.06 33.02 41.72 90.0 90.0 90.0
Wavelength
_diffrn_radiation_wavelength.wavelength
NA

Data quality metricsOverallOuterShell
Low resolution limit [Å]
_reflns.d_resolution_low _reflns_shell.d_res_low
7.571 1.300
High resolution limit [Å]
_reflns_shell.d_res_high
- 1.200
  - -
Rmerge
_reflns_shell.Rmerge_I_obs
- 0.740
  Rmeas - -
  Rpim - -
  Total number of observations - -
Total number unique
_reflns_shell.number_unique_all
- 1907
<I/σ(I)>
_reflns_shell.meanI_over_sigI_obs
- 2.70
Completeness [%]
_reflns_shell.percent_possible_all
- 75.6
Multiplicity
_reflns_shell.pdbx_redundancy
- 7.5
CC(1/2)
_reflns_shell.pdbx_CC_half
- 0.781

Refinement
PDB entry ID
_entry.id
7C4U
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
2020-05-18
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
7.6 - 1.200 Å
Rwork/Rfree
_refine.ls_R_factor_R_work _refine.ls_R_factor_R_free
0.2020 / 0.2159