Data quality metrics extracted from 1bmf.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 1BMF at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Source type
_diffrn_source.source
SYNCHROTRON
Source details
_diffrn_source.type
SRS BEAMLINE PX9.6
Synchrotron site
_diffrn_source.pdbx_synchrotron_site
SRS
Beamline
_diffrn_source.pdbx_synchrotron_beamline
PX9.6
Temperature [K]
_diffrn.ambient_temp
269
Detector technology
_diffrn_detector.detector
IMAGE PLATE
Collection date
_diffrn_detector.pdbx_collection_date
1993-09-15
Detector
_diffrn_detector.type
MARRESEARCH
Software
Data reduction
_software.classification
MOSFLM
Data scaling
_software.classification
CCP4
Phasing
_software.classification
MULTIPLE (ISOMORPHOUS REPLACEMENT)
Model building
_software.classification
MULTIPLE (ISOMORPHOUS REPLACEMENT)
Refinement
_software.classification
PROLSQ
General information
Spacegroup name
_symmetry.space_group_name_H-M
P 21 21 21
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
284.22 107.76 139.68 90.0 90.0 90.0
Wavelength
_diffrn_radiation_wavelength.wavelength
0.87000 Å

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
6.000
High resolution limit [Å]
_reflns.d_resolution_high
2.850
Rmerge
_reflns.pdbx_Rmerge_I_obs
0.098
  Rmeas -
  Rpim -
  Total number of observations -
Total number unique
_reflns.number_obs
96689
  <I/σ(I)> -
Completeness [%]
_reflns.percent_possible_obs
97.5
Multiplicity
_reflns.pdbx_redundancy
5.4
  CC(1/2) -

Refinement
PDB entry ID
_entry.id
1BMF
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
1996-03-13
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
6.0 - 2.850 Å