Data quality metrics extracted from 1bmc.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 1BMC at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Source type
_diffrn_source.source
ROTATING ANODE
Source details
_diffrn_source.type
RIGAKU RUH2R
Detector technology
_diffrn_detector.detector
DIFFRACTOMETER
Collection date
_diffrn_detector.pdbx_collection_date
1994-07
Detector
_diffrn_detector.type
ENRAF-NONIUS FAST
Software
Data reduction
_software.classification
MADNES
Refinement
_software.classification
X-PLOR
General information
Spacegroup name
_symmetry.space_group_name_H-M
C 1 2 1
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
53.79 61.98 69.97 90.00 93.67 90.00
Wavelength
_diffrn_radiation_wavelength.wavelength
1.54180 Å

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
25.000
High resolution limit [Å]
_reflns.d_resolution_high
2.500
Rmerge
_reflns.pdbx_Rmerge_I_obs
0.030
  Rmeas -
  Rpim -
  Total number of observations -
Total number unique
_reflns.number_obs
6911
  <I/σ(I)> -
Completeness [%]
_reflns.percent_possible_obs
86.0
Multiplicity
_reflns.pdbx_redundancy
2.0
  CC(1/2) -

Refinement
PDB entry ID
_entry.id
1BMC
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
1995-06-16
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
8.0 - 2.500 Å
Rwork/Rfree
_refine.ls_R_factor_R_work _refine.ls_R_factor_R_free
0.2200 / 0.3300