Data quality metrics extracted from 1apy.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 1APY at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Source type
_diffrn_source.source
ROTATING ANODE
Detector technology
_diffrn_detector.detector
IMAGE PLATE
Collection date
_diffrn_detector.pdbx_collection_date
1994-12-10
Detector
_diffrn_detector.type
RIGAKU
Software
Data collection
_software.classification
HKL
Data reduction
_software.classification
HKL
Refinement
_software.classification
X-PLOR
General information
Spacegroup name
_symmetry.space_group_name_H-M
P 61
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
98.4 98.4 134.5 90.0 90.0 120.0
Wavelength
_diffrn_radiation_wavelength.wavelength
1.54180 Å

Refinement
PDB entry ID
_entry.id
1APY
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
1995-06-14
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
8.0 - 2.000 Å
Rwork/Rfree
_refine.ls_R_factor_R_work _refine.ls_R_factor_R_free
0.1690 / 0.2240