Data quality metrics extracted from 260d.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 260D at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
Source type
_diffrn_source.source
ROTATING ANODE
Source details
_diffrn_source.type
MACSCIENCE
Detector technology
_diffrn_detector.detector
AREA DETECTOR
Collection date
_diffrn_detector.pdbx_collection_date
1994-12-06
Detector
_diffrn_detector.type
SIEMENS-NICOLET
Software
Data reduction
_software.classification
XENGEN (V. 2.0)
Refinement
_software.classification
X-PLOR
General information
Spacegroup name
_symmetry.space_group_name_H-M
P 61 2 2
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
38.97 38.97 77.34 90.0 90.0 120.0
Wavelength
_diffrn_radiation_wavelength.wavelength
NA

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
8.000
High resolution limit [Å]
_reflns.d_resolution_high
1.900
Rmerge
_reflns.pdbx_Rmerge_I_obs
0.031
  Rmeas -
  Rpim -
  Total number of observations -
Total number unique
_reflns.number_obs
2634
  <I/σ(I)> -
Completeness [%]
_reflns.percent_possible_obs
91.0
Multiplicity
_reflns.pdbx_redundancy
3.5
  CC(1/2) -

Refinement
PDB entry ID
_entry.id
260D
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
1996-05-21
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
8.0 - 1.900 Å
R
_refine.ls_R_factor_obs
0.1860
Rwork
_refine.ls_R_factor_R_work
0.1860
WARNING: no Rfree given?