Data quality metrics extracted from 208l.cif.gz by aB_cif2table1 from BUSTER (Global Phasing Ltd.). See also the PDBx/mmCIF dictionary and a MXLIMS-compatible JSON representation.


Experimental information for 208L at RCSB, PDBe, PDBj

Experiment
Method
_exptl.method
X-RAY DIFFRACTION
  The method used in the experiment.
Source type
_diffrn_source.source
ROTATING ANODE
  The general class of the radiation source.
Source details
_diffrn_source.type
MACSCIENCE M18X
  The make, model or name of the source of radiation.
Temperature [K]
_diffrn.ambient_temp
280
  The mean temperature in kelvins at which the intensities were
  measured.
Detector technology
_diffrn_detector.detector
IMAGE PLATE
  The general class of the radiation detector.
Collection date
_diffrn_detector.pdbx_collection_date
1993-02-01
  The date of data collection.
Detector
_diffrn_detector.type
MACSCIENCE
  The make, model or name of the detector device used.
Software
Data collection
_software.classification
WELMS
  The classification of the program according to its
  major function.
Data reduction #1
_software.classification
PROTEIN
  The classification of the program according to its
  major function.
Data reduction #2
_software.classification
WELMS
  The classification of the program according to its
  major function.
Data scaling
_software.classification
PROTEIN
  The classification of the program according to its
  major function.
Phasing
_software.classification
X-PLOR (3.1)
  The classification of the program according to its
  major function.
Model building
_software.classification
X-PLOR (3.1)
  The classification of the program according to its
  major function.
Refinement
_software.classification
X-PLOR (3.1)
  The classification of the program according to its
  major function.
General information
Spacegroup name
_symmetry.space_group_name_H-M
P 21 21 21
  Hermann-Mauguin space-group symbol. Note that the
  Hermann-Mauguin symbol does not necessarily contain complete
  information about the symmetry and the space-group origin. If
  used, always supply the FULL symbol from International Tables
  for Crystallography Vol. A (2002) and indicate the origin and
  the setting if it is not implicit. If there is any doubt that
  the equivalent positions can be uniquely deduced from this
  symbol, specify the _symmetry_equiv.pos_as_xyz or
  _symmetry.space_group_name_Hall data items as well. Leave
  spaces between symbols referring to
  different axes.
Unit cell parameters
_cell.length_{a,b,c} _cell.angle_{alpha,beta,gamma}
57.81
  Unit-cell length a corresponding to the structure reported in
  angstroms.
61.04
  Unit-cell length b corresponding to the structure reported in
  angstroms.
32.65
  Unit-cell length c corresponding to the structure reported in
  angstroms.
90.0
  Unit-cell angle alpha of the reported structure in degrees.
90.0
  Unit-cell angle beta of the reported structure in degrees.
90.0
  Unit-cell angle gamma of the reported structure in degrees.
Wavelength
_diffrn_radiation_wavelength.wavelength
1.54180
  The radiation wavelength in angstroms.
 Å

Data quality metricsOverall
Low resolution limit [Å]
_reflns.d_resolution_low
100.000
  The largest value in angstroms for the interplanar spacings
  for the reflection data. This is called the lowest resolution.
High resolution limit [Å]
_reflns.d_resolution_high
1.800
  The smallest value in angstroms for the interplanar spacings
  for the reflection data. This is called the highest resolution.
  Rmerge -
  Rmeas -
  Rpim -
  Total number of observations -
  Total number unique -
  <I/σ(I)> -
  Completeness [%] -
  Multiplicity -
  CC(1/2) -

Refinement
PDB entry ID
_entry.id
208L
Deposition date
_pdbx_database_status.recvd_initial_deposition_date
1996-03-26
Resolution
_refine.ls_d_res_low _refine.ls_d_res_high
6.0 - 2.200 Å
R
_refine.ls_R_factor_obs
0.1800
Rwork
_refine.ls_R_factor_R_work
0.1800
WARNING: no Rfree given?
Structure solution method
_refine.pdbx_method_to_determine_struct
MOLECULAR REPLACEMENT
Starting model (for MR)
_refine.pdbx_starting_model
NATIVE HUMAN LYSOZYME